Evolution (EVAW) - Water Heaters - Modulating, Indoor
Non-Condensing Ultra High Efficiency Hot Water Boilers & Heaters
The Thermal Solutions Evolution® Water Heater raises the standard by which other commercial water heaters shall be measured. The Evolution Water Heater combines a host of industry leading features along with an easy to service design that ensures long-term, dependable operation. And with the Thermal Solutions Products name behind it, you can trust the Evolution Water Heater to be a reliable, efficient source for hot water heating.
FOR MORE DOWNLOADABLE DOCUMENTS, PLEASE SELECT A MODEL SIZE
Items |
/Asset/evolution-w-more-white.jpg EVAW-750 Water Heater |
/Asset/evolution-w-more-white.jpg EVAW-1000 Water Heater |
/Asset/evolution-w-more-white.jpg EVAW-1500 Water Heater |
/Asset/evolution-w-more-white.jpg EVAW-2000 Water Heater |
||||
Input: BTUH | N/A 750,000 Btu/hr | N/A 1,000,000 Btu/hr | N/A 1,500,000 Btu/hr | N/A 2,000,000 Btu/hr | ||||
Output: BTUH | N/A 615,000 Btu/hr | N/A 820,000 Btu/hr | N/A 1,230,000 Btu/hr | N/A 1,640,000 Btu/hr | ||||
Fuel | N/A Natural Gas Propane | |||||||
Drawing |
N/A
Dimensional Drawing for Evolution - High Efficiency Water Heaters |
|||||||
Input - High Fire | N/A 750,000 Btu/hr | N/A 1,000,000 Btu/hr | N/A 1,500,000 Btu/hr | N/A 2,000,000 Btu/hr | ||||
Output - High Fire | N/A 615,000 Btu/hr | N/A 820,000 Btu/hr | N/A 1,230,000 Btu/hr | N/A 1,640,000 Btu/hr | ||||
Boiler | N/A 180 kW | N/A 240 kW | N/A 360 kW | N/A 481 kW | ||||
Inlet Gas Pressure (NG) | N/A 5 PSI Max. 7" W.C. Min. | N/A 5 PSI Max. 7" W.C. Min. | N/A 5 PSI Max. 7" W.C. Min. | N/A 5 PSI Max. 9" W.C. Min. | ||||
Inlet Gas Pressure (LP) | N/A 2 PSI Max. 7" W.C. Min. | N/A 2 PSI Max. 7" W.C. Min. | N/A 2 PSI Max. 7" W.C. Min. | N/A 2 PSI Max. 9" W.C. Min. | ||||
Electrical Supply Options (On-Off) | N/A | |||||||
Electrical Supply Options (Modulating) | N/A 120v/1ph/60hz - 7.5 Amps 208v/1ph/60hz - 6.6 Amps 208v/3ph/60hz - 6.0 Amps 230v/1ph/60hz - 6.4 Amps 230v/3ph/60hz - 6.0 Amps 460v/3ph/60hz - 3.0 Amps | |||||||
ASME Design Data | N/A Max. 160 PSIG & 250ºF | |||||||
Trim & Controls | N/A Blower Motor, 1-1/2 HP Combustion Air Switch Flame Safeguard High Temperature Limit High/Low Gas Press Switches LWCO Flow Switch Modulating Gas Valve Operating Control Pilot Gas Regulator Pilot Gas Valve Pilot/Leak Test Cocks Pressure & Temperature Gauge Relief Valve VFD | |||||||
Double Block & Bleed (D.B.& B.) Gas Train Option | N/A (1) Motorized & (1) Solenoid Gas Valve N.O. Vent Valve | |||||||
IRI W/ P.O.C. Gas Train Option | N/A (2) Motorized Gas Valves with proof of closure switches Flame Safeguard that recognizes proof of closure valves N.O. Vent Valve | |||||||
Shipping Weight | N/A 1172 Pound | N/A 1260 Pound | N/A 1402 Pound | N/A 1536 Pound | ||||
|