Thermal Solutions Boiler Control
Boiler Control Systems
The perfect interface between boilers and your heating system. Operates as stand alone device on all Evolution (EVS, EVSW or EVCA) or Solaris product models or easily integrates into todays BMS (Building Management Systems) with Modbus protocol. TSBC controls modulation of firing rate locally or by remote, has simple peer-to-peer staging with plug-and-play RJ11 telephone cable, and uses advanced PID (Proportional Integral Derivative) logic to optimize system efficiency by precisely matching boiler output to current building heating load. Learn more features of this control.....
Unit of Measure
Items |
/Asset/TSBC.JPG 101171-03 Thermal Solutions Boiler Control Assembly |
/Asset/TSBC.JPG Busman GMC-5A Replacement Fuse |
/Asset/TSBC.JPG 101935-01 Immersion Temperature Sensor |
/Asset/TSBC.JPG 801SOL0012 Outdoor Temperature Sensor |
||||
Description |
N/A
Individual boiler operating and modulation rate control and modulating lead-lag controller. Built to UL and CSA standards. |
N/A The perfect interface between boilers and your heating system. Operates as stand alone device or easily integrates into todays BMS (Building Management Systems) with Modbus protocol. TSBC controls modulation of firing rate locally or by remote, has simple peer-to-peer staging with plug-and-play rj11 telephone cable, and uses advanced PID (Proportional Integral Derivative) logic to optimize system efficiency by precisely matching boiler output to current building heating load. Learn more features of this control..... | N/A 1/2" NPT 10K OHM at 25C, NTC Thermistor Type, Resistance Ratio R0/R50 = 9.07 temperature sensor for measuring water temperature in supply manifold, return manifold or system header. |
N/A
10K OHM at 25C, NTC Thermistor Type, Resistance Ratio R0/R50 = 9.07 outdoor air temperature sensor with weather proof box and protective sleeve. For use in outdoor reset applications. |
||||
Mechanical Panel Assembly | N/A 8 inches wide x 6 inches tall | N/A | N/A | N/A | ||||
Mechanical Message Display | N/A 2 x 16 Character, 8.06 mm characters | N/A | N/A | N/A | ||||
Environmental Operating Temperature | N/A 32 to 140 ºF0 to 60 ºC | N/A | N/A | N/A | ||||
Environmental Storage Temperature | N/A -20 to 150 ºF-28 to 65 ºC | N/A | N/A | N/A | ||||
Environmental Humidity Limits | N/A 15 to 95% (non-condensing) | N/A | N/A | N/A | ||||
Environmental Front Panel | N/A NEMA 1 | N/A | N/A | N/A | ||||
Electrical Power Supply (AC) | N/A 24 V | N/A | N/A | N/A | ||||
Note | N/A All 24Vac Inputs must be connected to the same phase as (PR) Internal Power Consumption: 8 VA max, 24 Vac (+/- 15%), and 6 VA max, 12 Vdc 0.5A for LO, VI, BP, SP and SO | N/A | N/A | N/A | ||||
Real Time Clock | N/A Battery Backed, 2 yrs without AC Power | N/A | N/A | N/A | ||||
Communications | N/A Boiler Peer to Peer - RS485, RTU Programming - ISP Port | N/A | N/A | N/A | ||||
Time and Date Battery |
N/A
The battery is only used to power the time of day and date clock chip when the 24 Vac power is removed from the TSBC. When new, the battery can power the clock for approximately 2 years with 24 Vac power removed. The clock battery has a shelf life of approximately 6 years (without ac applied). TSBC configuration and user data are stored in non-volatile EEPROM. This battery is NOT used to retain this memory. The battery is located at the back of the TSBC for easy replacement. |
N/A | N/A | N/A | ||||
|